EasyManua.ls Logo

Panasonic WH-UD09HE5 - Installer Menu: Service Setup - Sterilization & Pump; Sterilization Schedule and Temperature Settings; Pump Maximum Speed Configuration; Pump Down Operation Setup

Panasonic WH-UD09HE5
108 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
22
Menu Default Setting Setting Options / Display
Sterilization
Sterilization may be set for 1 or
more days of the week.
Sun / Mon / Tue / Wed / Thu / Fri / Sat
Sterilization: Time
Time of the selected day(s) of the week to
sterilize the tank
0:00 ~ 23:59
Sterilization: Boiling temp.
65 °C
Set boiling temperatures
for sterilize the tank.
Sterilization: Ope. time (max)
0:10
Set sterilizing time
(in hours and minutes)
Installer setup Service setup
1
Pump maximum speed
To set the maximum speed of
the pump.
Setting the ow rate, max. duty and operation
ON/OFF of the pump.
Flow rate: XX:X L/min
Max. Duty: 0x40 ~ 0xFE,
Pump: ON/OFF/Air Purge
2
Pump down
To set the pump down operation.
Pump down operation
ON
Menus
For installer

Table of Contents

Related product manuals