11
Item Unit Outdoor Unit
Type Hermetic Motor
Motor Type Brushless (4-poles)
Compressor
Rated Output kW 4.50
Type Propeller Fan
Material PP
Motor Type DC (8-poles)
Input Power W —
Output Power W 60
Fan
Fan Speed rpm
Cooling: 600 (Top), 640 (Bottom)
Heating: 510 (Top), 550 (Bottom)
Fin material Aluminium (Pre Coat)
Fin Type Corrugated Fin
Row × Stage × FPI 2 × 51 × 18
Heat Exchanger
Size (W × H × L) mm 903.7 × 1295.4 × 38.1
ø Three
V 400
Power Source (Phase, Voltage, Cycle)
Hz 50
Condition
(Ambient/Water)
A35W7 A7W35 A2W35
Input Power
kW Cooling: 3.51 Heating: 2.53 Heating: 3.31
Maximum Input Power For Heatpump System kW 5.85
Power Supply 1 : Phase (Ø) / Max. Current (A) / Max. Input Power (W) 3Ø / 8.8 / 5.85k
Power Supply 2 : Phase (Ø) / Max. Current (A) / Max. Input Power (W) 3Ø / 13.0 / 9.00k
Power Supply 3 : Phase (Ø) / Max. Current (A) / Max. Input Power (W) — / — / —
Starting Current A 5.3
Condition
(Ambient/Water)
A35W7 A7W35 A2W35
Running Current
A Cooling: 5.3 Heating: 3.8 Heating: 5.0
Maximum Current For Heatpump System A 8.8
Power Factor
Power factor means total figure of compressor and
outdoor fan motor.
% Cooling: 96 Heating: 96 Heating: 96
Number of core —
Power Cord
Length m (ft) —
Thermostat Electronic Control
Protection Device Electronic Control