212
During reinstall Flow Sensor
Make sure arrow point to left
Make sure the flow sensor is not slanting
17.9 To Remove Water Pump and Bottle Complete
Water Pump
1. Disconnect CN-PUMP1 from
electronic controller.
2. Loosen the nut.
4. Remove 2 retaining rings, then pull out the water pump.
3. Remove 2 screws.
Bottle Complete
5. Disconnect CN-OLP1 and
6. Remove 2 retaining rings.
7. Remove 2 screws then remove
bottle complete.
lead wire HT1-L3 (Red and White)
.