EasyManua.ls Logo

Panasonic WH-UD09HE8 - Page 177

Panasonic WH-UD09HE8
241 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
177
16.5.17 Abnoraml External Thermistor 2 (H68)
Malfunction Caused:
1 Faulty connector connection.
2 Faulty room temperature zone 2 sensor.
3 Faulty indoor sub PCB.
Abnormality Judgment:
Continue for 5 seconds.
YES
Correct external thermistor 2 sensor
connector
NO
Change external thermistor 2
NO
YES
Check resistance of external thermistor 2 compare against
characteristic of external thermistor same?
Abnormal external thermistor 2
Check connector CN205 on sub PCB normal?
Change sub PCB
Troubleshooting:
For safety reason and to prevent component breakdown,
always switch off the power before remove and connect the component.
Caution