16
Menus
For installer
Menu Default Setting Setting Options / Display
Control pattern Advanced parallel Heat Yes
Buffer Tank is activated only after selecting
“Yes”.
-8 °C
Set the temperature
threshold to start the
bivalent heat source.
0:30
Delay timer to start
the bivalent heat
source
(in hour and minutes).
-2 °C
Set the temperature
threshold to stop the
bivalent heat source.
0:30
Delay timer to stop
the bivalent heat
source
(in hour and minutes).
Control pattern Advanced parallel DHW Yes
DHW Tank is activated only after selecting
“Yes”.
0:30
Delay timer to start
the bivalent heat
source
(in hour and minutes).
5.9
External SW
No