Why is my Panasonic WH-UDZ05KE5 operation delayed a few minutes after restarting?
- Ddaniel18Sep 9, 2025
The delay after restarting your Panasonic Heat Pump is a protection mechanism for the compressor.
Why is my Panasonic WH-UDZ05KE5 operation delayed a few minutes after restarting?
The delay after restarting your Panasonic Heat Pump is a protection mechanism for the compressor.
Why does my Panasonic WH-UDZ05KE5 Heat Pump system not heat up instantly?
The system may take some time to heat up the water if it starts operating at a cold water temperature.
How to improve HEAT/COOL mode efficiency in Panasonic WH-UDZ05KE5?
If your Panasonic Heat Pump system is not working efficiently in HEAT/*1, *2 COOL mode, make sure you've set the temperature correctly. Also, close the panel heater/cooler valve and clear any obstructions in the air inlet and air outlet vents of the outdoor unit.
Why is COOL mode unavailable on my Panasonic WH-UDZ05KE5?
The system has locked to operate in HEAT mode only.
Why doesn't my Panasonic WH-UDZ05KE5 heat up instantly?
The system will take some time to heat up the water if it starts to operate at cold water temperature.
Why is my Panasonic Heat Pump system hard to heat up?
If your Panasonic Heat Pump is hard to heat up, it may be due to several reasons. When the panel and the floor are heated simultaneously, warm water temperature may decrease, which may reduce the heating ability of the system. When the outdoor air temperature is low, the system may need longer time to heat up. Check if the discharge outlet or intake inlet in the outdoor unit is blocked by some obstacle, such as a pile of snow. When the preset water outlet temperature is low, the system may need longer time to heat up.
What to do if the Operation LED is not lit on my Panasonic Heat Pump Remote Controller?
If the Operation LED is not lit or nothing is displayed on the Panasonic Heat Pump Remote Controller, check if the power supply is working correctly or if a power failure has occurred.
What does it mean if *1, *2 COOL mode is unavailable on my Panasonic WH-UDZ05KE5?
If *1, *2 COOL mode is unavailable on your Panasonic Heat Pump, the system has been locked to operate in HEAT mode only.
What to do if my Panasonic Heat Pump operation in HEAT/COOL mode is not working efficiently?
If your Panasonic Heat Pump isn't heating or cooling efficiently, make sure you set the temperature correctly, close the panel heater/cooler valve, and clear any obstructions in the air inlet and air outlet vents of the outdoor unit.
Why does my Panasonic WH-UDZ05KE5 Heat Pump start automatically?
If the Panasonic Heat Pump operation starts automatically when the timer is not set, it means the sterilization timer has been set.
Model | WH-UDZ05KE5 |
---|---|
Category | Heat Pump |
Refrigerant | R32 |
Type | Air-to-Water |
Heating Capacity | 5.0 kW |
EER | 3.8 |
Covers general warnings, power supply, electrical safety, unit care, and handling.
Details safety for R32 refrigerant, service procedures, leak detection, and component repair.
Outlines safe practices for refrigerant removal, charging, decommissioning, and recovery processes.
Explains various operating modes, icons, and temperature zone displays.
Details settings for room/tank heaters, sterilization, and system performance monitoring.
Details settings for bivalent connections, solar integration, and external controls.
Details the setup and configuration of various external meters for energy monitoring.
Lists common operating symptoms, their causes, and preliminary checks before calling service.
Provides a comprehensive list and explanation of system error codes.