NV500-EI07 Printed in Canada 07/2012
NV500 High-Performance Digital Infrared Motion Detector: Installation Manual V1.0
Jumper Settings
The NV500 features 4 pre-programmed profile settings.
The number associated with the profile (1 to 4) depicts the
number of LED flashes when changing jumper settings.
1. Normal (DEFAULT): This profile allows for faster
detection. Use this profile only in normal environments
that have minimal interference.
2. Moderate Risk: This profile provides better false alarm
rejection. Dual-edge processing requires balanced
detection from both sensor’s elements and requires that a
beam must be fully crossed even at close range.
3. Pet Immunity: Use the Pet Immunity profile if you have
pets that weigh up to 16 kg (25 lb).
4. Harsh: Use the Harsh profile when the detector is
installed in high-risk environments (potential interference)
and to provide greatly increased false alarm immunity.
SETTING APSP EDGE JUMPER
1. NORMAL NORMAL SINGLE
2. MODERATE NORMAL DUAL
3. PET IMM. HIGH SINGLE
4. HARSH HIGH DUAL
LED ON
Power-up Sequence
1) LED and relay will toggle on/off for 4 seconds.
2) Sensitivity level indication: 1 to 5 short flashes to
indicate trimpot position (see B: Sensitivity Settings).
3) Jumper setting indication. 1 to 4 short flashes to
indicate jumper setting (see C: Jumper Settings).
4) Detector is ready for alarm detection. Total power-up
sequence = 10 seconds.
Wiring Diagram
N.C. COM BLK
RED TAMPER
ALARM OUTPUT 12Vdc
+
N.C.
NV500
LED Feedback
During alarm: ON for 3 seconds
During sensitivity adjustment: See Sensitivity Settings
During power-up sequence: See Power-up Sequence
Sensitivity Settings
Configure sensitivity via trimpot. Adjust from 1 (lowest sensitivity) to 5
(highest sensitivity), default = 3. The detector must be installed at 2.1
meter or higher).
Viewing sensitivity settings: After power-up, or right after setting the
trimpot to a new sensitivity level, the LED will flash a consecutive amount
of times to show the setting, then adjust the setting accordingly. Thus if
the sensitivity is set to 3, the LED flashes 3 times.
Turn clockwise = Increase sensitivity
Turn counterclockwise = Decrease sensitivity
Warning: The sensitivity trimpot is fragile. Do not overtorque.