Page 18 Configuring the PCS250
Configuring WinLoad Access
The PCS250 GPRS/GSM Communicator Module provides remote
access for upload and download with WinLoad via a GPRS
connection. The following site specific sections must be
configured for WinLoad access.
Note: In the case where a reportable event occurs while a WinLoad
session is active via GPRS, the communication is terminated to allow
event reporting.
Programming GSM Reporting Options
The following sections describe the options that must be
programmed in the panel for GSM reporting.
Note: The primary phone number is configured via section [815]; the
backup phone number is configured in section [817]. A land/GSM
account number must be defined in sections [811] and [812] for MG/
SP/E and for EVO in sections [3061] through [3068].
MG/SP/E EVO Feature Details
[920] [2966] Software port Default: 10000
[927] [3013] Password Default: admin
MG/
SP/E
EVO Details
[805] [2950] [1] Off + [2] Off = Landline only (default)
[1] Off + [2] On = Landline primary / GSM
backup
[1] On + [2] Off = GSM primary / landline
backup
[1] On + [2] On = GSM only

Other manuals for Paradox PCS250

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Paradox PCS250 and is the answer not in the manual?

Paradox PCS250 Specifications

General IconGeneral
CommunicationGSM/GPRS
DisplayNo
BatteryNo
CameraNo
NetworkGSM/GPRS
BluetoothNo
FM RadioNo

Related product manuals