EasyManuals Logo

Paradox PCS250 User Manual

Paradox PCS250
44 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #31 background imageLoading...
Page #31 background image
Module Supervision Page 31
View GSM IP Information
It is possible to view the following GSM IP information in Master
Programming:
IP Address: Access this to determine which IP address to
enter in the WinLoad or NEware GPRS connection settings.
The IP address is determined automatically when the PCS250
connects to the GSM network. In order to properly read the
IP address assigned, the GPRS LED must be on.
IP Port: Access this to determine which IP port to enter in the
WinLoad or NEware GPRS connection settings. This is the
port that the module will listen for incoming GPRS
communication. This port is programmed in section [2966]
with Digiplex EVO or [920] with MG Series, SP Series,
E-Series.
User PC Software Password: This password is needed to
connect to the control panel using the NEware software. This
password is determined in the NEware software.
SMS Phone Number Special Characters for EVO panels
* [stay]
#[force]
+[arm]
Other panels
*[off]
# [bypass]
+[mem]
Event Call Options
Option Events that send SMS
[1] Any Alarm
[2] Arming and Disarming
[3] Any Trouble
[4] Any Trouble Restore
[5] to [8] Future Use

Other manuals for Paradox PCS250

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Paradox PCS250 and is the answer not in the manual?

Paradox PCS250 Specifications

General IconGeneral
CommunicationGSM/GPRS
DisplayNo
BatteryNo
CameraNo
NetworkGSM/GPRS
BluetoothNo
FM RadioNo

Related product manuals