Page 22 Configuring the PCS250
Enter the following command to view the SMS reporting settings
(VSMS):
1) Send the VSMS command:
P[
PASSWORD].VSMS.[CALLBACK PHONE NUMBER]
(e.g., Padmin.VSMS.5145552222)
2) If the SMS reporting parameters are programmed properly,
the following SMS will be received:
[S
ITE ID]
SMS#: [GSM
MODEM TELEPHONE # (5145551111)]
Password: [IPRS-7
PASSWORD (123456)]
Status: [IPRS-7
REGISTRATION STATUS]
3) If nothing is programmed or the programmed information
has been cleared, the following SMS will be received:
[
SITE NAME SMS RECEIVER NOT PROGRAMMED]
Enter the following command to clear the programmed SMS
parameters:
P[password].SMS.clear
SMS commands reference:
IMPORTANT: Do not register the Backup IP receiver (SP-Series: [949],
EVO-Series: [2991]); doing so will delete the PCS250 SMS
configuration.
SMS - Program the
receivers SMS
parameters
P[password].SMS.[GSM modem
telephone #].[IPRS-7 password]
VSMS - View the SMS
reporting settings
P[password].VSMS.[callback phone
number]
Clearing the
programmed SMS
parameters
P[password].SMS.clear