www.charltonandjenrick.co.uk 17 LT5052 (ISS 5)
WARNING
This PARAGON 2000 Plus MANUAL TURBO requires an electricity supply (220-240V ~ 50Hz) and must be
protected by a 3A fuse. All external wiring between the appliance and the electrical supply must comply with the
current I.E.E. regulation.
A means of electrical isolation should be readily accessible to the user.
The appliance must be installed on a suitable outside wall.
Where the appliance is fitted at floor level a non-combustible hearth must be provided to comply with the
building regulations or a suitable proprietary fire surround with a 100
o
C rating.
A fire fret must be used with this appliance and see Section One.
The appliance incorporates a safety device in the form of an Oxygen Depletion System which constantly
monitors the oxygen in the room and will cause the fire to switch off if the oxygen level reduces, for instance due
to insufficient ventilation or a blocked flue. THIS DEVICE MUST NOT BE OVERRIDDEN.
This appliance has a naked flame, as with all such fires it is recommended that a fireguard should be used for the
protection of children, the elderly and infirm. Fireguards should conform to BS 6539 (1984) (Fireguards for use
with solid fuel appliances).

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Paragon 2000 Plus Turbo Manual and is the answer not in the manual?

Paragon 2000 Plus Turbo Manual Specifications

General IconGeneral
BrandParagon
Model2000 Plus Turbo Manual
CategoryIndoor Fireplace
LanguageEnglish

Related product manuals