P a g e | 20
P10 INSTALLATION INSTRUCTIONS
Using rawl plugs and wood screws retain the fire box via the 6mm holes within the slip brackets.
None combustible slips can now be fitted up to the edge of the fire place frame.
B-Dry lined hole in the wall.
Remove the outer plaster board skin and any
stud work to expose an opening
Size of 770mm wide x 790mm high.
1080
980
85
Using appropriate heat resistant board. Board up to the fireplace
frame. The top shaded area below should be one piece with no joints.
790
700