I. SPECIFICATIONS
VIOS
SPECIFICATIONS
Weight .......................................................................................................................................................................................3 lbs.
Dimensions: .........................................................................................................................................................6.5 x 6.5 x 3.75 in.
Electrical Requirements: ................................................................................................................................120V AC, 60Hz, 1.5A
Power Wattage: ....................................................................................................................................... 80 W, under normal load
Ambient Operating Conditions: ....................................................................................................10°C to 40°C, (50°F to 104°F)
Power cord length: ......................................................................................................................................................................5 ft.
TRANSPORT/STORAGE CONDITIONS:
Ambient temperature: ................................................................................................................ -40°C to 70°C, (-40°F to 158°F)
Relative Humidity: ..........................................................................................................................................................10% to 95%
Atmospheric Pressure: ....................................................................................................................................500 hpa to 1060 hpa
EXPLANATION OF SYMBOLS
Attention: Read all “Instructions for Use” before operation: .........................................................................
Insulation enclosed Class II equipment: ...........................................................................................................
Type “B” Protection from electrical shock: ......................................................................................................
Do not dispose of in unsorted municipal trash.
Please consult local laws and regulations for proper disposal:........................................................................
Power Switch: ....................................................................................................................................................
“On” Position (compressor running): ..............................................................................................................
“Off ” Position (compressor is not running): ....................................................................................................
NOTE: WHEN SWITCH IS IN THE “OFF” POSITION AND THE COMPRESSOR IS NOT RUNNING, THERE WILL
STILL BE ELECTRICAL POTENTIAL INSIDE THE COMPRESSOR HOUSING. TO REMOVE POWER FROM THE
COMPRESSOR, THE POWER PLUG MUST BE REMOVED FROM THE POWER SOURCE.
1 Measured by 7-stage Cascade Impactor, with membrane fi lter for 8th stage, equipped with a USP <601> throat, at 28 LPM continuous inspiratory fl ow.
2 Mass Median Aerodynamic Diameter
3 Respirable Mass delivered (0.5 – 5 µm) as a percentage of initial fi ll
4 Total Dose delivered by the nebulizer and captured by the impactor
AEROSOL PERFORMANCE
PARI Vios
TM
compressor with PARI LC
®
Sprint nebulizer
1
Albuterol Sulfate Ipratropium Bromide Cromolyn Sodium
MMAD (µm)
2
1.63 2.03 1.63
RM (% of ll)
3
21.30 22.07 16.20
Total Dose (µg)
4
697.4 142.0 4394.6