Start-up procedures
This chapter contains instructions for action to be taken in connection with the initial 
start.
WARNING
Risk of injury!
If the control system is not fitted properly, the machine could move uncontrollably. The 
machine’s engine shall not be started before the control system is completely fitted and 
its signals are verified.
Starting the control system
Start the control system as follows:
• Prior to start, all modules and cables are to be fitted correctly. 
• Check fuses, i.e. make sure that the supply voltage to the modules is equipped with 
the correct fuse.
• Make sure that connections for supply voltage and return lines are correct in the 
cable’s conductor joint. 
• Make sure the emergency stop works.
The emergency stop should disconnect the supply voltage to all modules. 
Alternatively, the emergency stop may also shut off the diesel engine or a dump valve, 
and with that depressurize the hydraulic system.
Prepare for system start
WARNING
Make sure no one is in dangerous proximity to the vehicle to avoid
injuries when it starts.
Prepare for the initial system start as follows:
• The engine for the hydraulic system’s pump shall be in off position.
• Make sure that all connectors are properly connected. 
• Turn on the control system.
• Make sure that voltage is being supplied to all modules, the green diode shall be 
illuminated on all modules. Also make sure that master is in contact with all 
modules by reading the master’s display. Error messages are displayed if the master 
is not in contact with one or more of the modules. 