xxv
IQAN-Lx Technical Overview
Appendix A
Instruction book, IQAN-Lx
DOUT (on/off output)
Load current 400 mA
Voltage drop (V
BAT
-V
DOUT
)
load I
L
= 0.5A
load I
L
= 2A
0.2
0.8
V
Off-State output current: 10 µA
Max load inductance: 1000 mH @ 400 mA
Short Circuit current limit 1.2 A
I/O
T
A
= +25 °C (unless otherwise specified)
Parameter
Limit values
Unit Remark
min. typ. max.