5. Servicing
The recommended Service procedures identified in table 5.2 and all other repair and calibration work should be undertaken by a
Parker domnick hunter trained, qualified and approved engineer.
5.1 Cleaning
Clean the equipment with a damp cloth only and avoid excessive moisture around any electrical sockets. If required you may
use a mild detergent, however do not use abrasives or solvents as they may damage the warning labels on the equipment.
5.2 Service Intervals
Check Replace
Description of Service Requirements Typical Recommended Service Interval
Component Operation
Daily
Weekly
3 Months
6 Months
12 Months
36 Months
Dryer Check POWER ON indicator is illuminated.
Dryer
Check STATUS / FAULT indicators located on the
controller.
Dryer Check for air leaks.
Dryer
Check the pressure gauges during purging for excessive
back pressure.
Dryer
Check the condition of electrical supply cables and
conduits.
Dryer Check for cyclic operation.
Dryer
Replace the active exhaust silencers.
Recommended Service A
Filtration
Replace the inlet, outlet and control air filters, and service
drains.
Recommended Service B
Dryer
Replace / Calibrate dewpoint transmitter (DDS Units
only).
Recommended Service C
Dryer
Replace the valve seats and seals.
Recommended Service D
Dryer
Replace the Desiccant.
Recommended Service E