MX 102 - MX110 User Guide
6
2.1 Technical Specification
This specification is valid when the equipment is located, installed, operated, and maintained as specified within this user
guide.
Stated flows are for operation at 7 bar g (102 psi g / 0.7 MPag) with reference to 20 ºC, 1 bar (a), 0% relative water vapour pressure.
2.1.1 Dimensions
Refer to diagram A1 in Annex A for dimensions and weights.
Specific
Parameter Units MX102c - MX103 MX104 - MX110
Minimum Inlet Pressure
bar g
(psi g / MPa g)
4
(58 / 0.4)
Maximum Inlet Pressure
bar g
(psi g / MPa g)
13
(190 3 / 1.3)
Inlet Temperature
ºC
(ºF)
2 -50
35 - 122
Inlet Connection Inches 2" 2 1/2"
Outlet Connection Inches 2" 2 1/2"
Flowrate (7 barg / 100 psi g / 0.7 MPa g @ 35 ºC / 95 ºF)
Model
Dewpoint -40ºC (-40 ºF) Dewpoint -70 ºC (-100 ºF) Dewpoint -20 ºC (-4 ºF)
cfm
m
3
/ min m
3
/ hour
cfm
m
3
/ min m
3
/ hour
cfm
m
3
/ min m
3
/ hour
MX102c 240 6.80 408 168 4.76 285 264 7.48 449
MX103c 360 10.19 611 252 7.14 428 396 11.21 673
MX103 450 12.75 765 315 8.92 535 495 14.02 841
MX104 600 17.00 1020 420 11.89 713 660 18.69 1121
MX105 750 21.25 1275 525 14.87 892 825 23.36 1402
MX106 900 25.50 1530 630 17.84 1070 990 28.03 1682
MX107 1050 29.75 1785 735 20.82 1248 1155 32.70 1962
MX108 1200 34.00 2040 840 23.79 1427 1320 37.38 2243
MX109 - - - 945 26.76 1605 - - -
MX110 - - - 1050 29.73 1783 - - -
Electrical
Parameter Units MX102 - MX110
Supply Voltage V ac 100 - 240 V ac 50 / 60Hz ± 10%
Power W
MXS = 18 W Max
MXA = 35 W Max
Environmental
Parameter Units MX102 - MX110
Temperature
ºC
(ºF)
2 - 45
35 - 113
Humidity -
50% @ 40 ºC
(80% MAX 31 ºC)
IP Rating - IP65 / >NEMA 13
Pollution Degree - 2
Installation Category - II
Altitude
m
(ft)
<2000
(6562)
Noise dB(A) <80 dBA
Before continuing with the installation and commissioning of this equipment:
Ensure that it is correctly sized for the inlet pressure, taking into consideration the pressure drop caused by the valves, pipes
and filters within the system. Allowance should be made for purge air loss. The dryer should be typically sized at 1 bar
(14 psi / 0.1 MPa) below nominal compressor output pressure.
The purge air flow is factory set for 6 bar g (87 psi g) minimum system pressure. Should the minimum supply pressure be
higher or lower than this figure the purge air flow must be reset in order to maintain the specified dewpoint. Please contact
your local Parker domnick hunter office for assistance.
Ensure that the electrical supply voltage and frequency meet the requirements detailed within this specification and on the
equipment rating plate.