2
Figure 2
PSG SERIES SYSTEM
Inlet
Plenum
Unicells
Odor 
Control
Outlet 
Plenum
System
Blower
Main Electrical 
Panel
Structural
Steel Skid
Power Pack Enclosures 
with Indicator Lights
Baffle Filters
Wash Water Supply
Pipe Connection
Face & Overhead
Wash Headers
Each pack supplies power to a discrete module of unicells with 
a dedicated, externally mounted indicator light that illuminates to 
indicate normal operation. The PSG power pack meets UL safety 
standards. In the event of a short circuit or overload condition to the 
output side, the power pack’s high voltage collapses and the indicator 
light is in the flashing mode. Upon removal of the overload, the power 
pack automatically returns to normal and the indicator light will be 
illuminated. The power pack is self-protecting against overloads (e.g. 
dirty components, short circuits in ionizer and cell circuits) and is self 
regulating when the AC voltage supply varies from 90 to 132 VAC. 
1.4.2  Unicell  Ionizer  Section                                                                                                                  
Each unicell supports ten (10) 10 mil tungsten steel ionizer wires 
spring mounted and centered between aluminum ground plates.  
Refer to Figure 6. When high DC voltage is applied to the wires, a 
powerful field charges contaminated particles.  Ionizer standoff con-
voluted insulators are part of the ionizer wire support bar(s) which 
separates high voltage from grounded chassis. 
1.4.3  Unicell  Collector  Cell  Section                                                                                                    
Each unicell contains a series of parallel plates, alternately charged 
and grounded, whose planes are in-line with the direction of airflow.  
Refer to Figure 6. Charged plates are connected electrically and sus-
pended from four triangular shaped insulators on each end of the 
unicell. The ground plates are independently supported.