Trouble shooting
Problem Possible cause Remedy
Pressure
cleaner is not
operating
ON / OFF switch (10) is
turned off
Check ON / OFF switch (10)
Damaged power supply
cable (6)
Switch off the equipment and disconnect
from the mains. Check power supply
cable (6) for damage. If necessary have
the power supply cable (6) replaced by
a qualied electrician.
Mains fault
Check the electrical system for conform-
ity with the data on the rating plate.
Pressure clean-
er does not
generate any
pressure
Air trapped in the pressure
cleaner
Switch on the equipment with the jet gun
and with no nozzle until bubble-free wa-
ter comes out.
Drop in the water mains
pressure
Check the water mains.
Severe pres-
sure uctua-
tions
High-pressure nozzle (17)
is dirty
Rinse the high-pressure nozzle (17) with
water. If necessary clean the nozzle hole
with a needle.
Leaks in the
water system
Connections not tted cor-
rectly
Switch off the equipment and disconnect
from the mains. Reconnect the equipment
to the water pipes (cf. “Initial Operation/
Set-Up”)
Water connection (9) leaks
Switch off the equipment and disconnect
from the mains. Replace the water con-
nection (9) inc. gasket (cf. “Spare Parts”)
Spare Parts Order
When buying parts for the pressure cleaner, use the service address given.
Please enter your machine type and the item number of the part you are ordering.
Item Description ....................................................... Product No.
1 Jet gun ..........................................................................91097399
3 High-pressure hose ..........................................................91097400
13 Quick connector for garden hose adaptor .........................91097401
17 Turbo dirt blaster ............................................................91097403
18 Standard Vario nozzle.....................................................91097404
19 Rotating wash brush ........................................................91097405
9 Water connection w/ strainer frame..................................91097408

Table of Contents

Other manuals for Parkside PHD 150 B2

Related product manuals