EasyManua.ls Logo

Parkside PHDP 180 C2 - Battery Insertion and Replacement; Tools for Battery Insertion; Battery Insertion Steps

Parkside PHDP 180 C2
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
GB
MT
34
• Pressure setting (20)
The trigger gun pipe can be turned
through three levels.
• low pressure
• high pressure
• LC display (15)
The display shows the set pressure
when the switch lever is pulled.
high pressure for walls and
foam
medium pressure for vehicles
low pressure for sensitive ob-
jects
Bow-type handle (2)
With the bow-type handle pulled out, you
can conveniently roll the device.
• Pulling out the handle:
Pull the bow-type handle up.
• Pulling in the handle:
Press the release (3) on the bow-type
handle and pull the bow-type handle
down.
Inserting the batteries
Insert the batteries in the battery compart-
ment before using the device for the first
time.
Tools required
• Phillips screwdriver (not included)
Procedure
1. Remove the screw from the battery
compartment cover (16).
2. Remove the cover of the battery com-
partment.
3. Insert the batteries (35) in the battery
compartment. Pay attention to the cor-
rect polarity when inserting the batter-
ies in the battery compartment.
4. Press the switch lever (17) on the trig-
ger gun (1).
The LC display shows the selected pres-
sure. If the LC display is not displaying
anything, check the direction of the bat-
teries.
5. Insert the cover of the battery compart-
ment.
6. Fasten the cover of the battery com-
partment using the screw.
Setting up the device
1. Place the device horizontally on a level
surface.
2. Insert the high-pressure hose through
the guide for the high-pressure hose
(9).
3. Insert the high-pressure hose into the
high-pressure connection on the trigger
gun (1).
Do not guide the hose through the
bow-type handle (2) as to not obstruct
the bow-type handle.
Establishing a water supply
You have two options to supply the device
with water:
• Household water connection
• Suctioning standing, clean water, e.g.
rain barrel
Household water connection
Requirements
• Supply hose: Garden hose with fitted
garden hose adaptor (34); 13mm
(½"); length between 5m and 30m
• Minimum pump capacity: 540l/h
(9l/min)
• System separator
A system separator (check valve)
prevents the backflow of water and
cleaning agent into the drinking water
pipeline.
• According to current regulations, a
pressure washer must never be con-
nected to the drinking water network

Table of Contents