Nominal sizes available for light commercial applications.
Product listings with UL, ARI, and CEC.
Electrical supply voltage and phase options for different sizes.
Description of the totally enclosed, permanent split capacitor fan motor.
Details on the weather-protective, prepainted steel cabinet construction.
Features of the copper tube, aluminum fin coil and vertical air discharge.
Protection features including internal overloads and pressure relief valve.
Control board that monitors electrical phase for compressor protection.
Brass front seating type valves for quick connections and pressure checks.
Access to electrical controls and major components via panels.
Standard 1-year parts and 5-year compressor warranty.
Identifies the unit as an Electric Air Conditioner.
Specifies voltage and phase for the unit.
Indicates the refrigerant used (R22).
Specifies the cooling capacity in tons (036, 048, 060).
Designations for unit series and variations.
Operating and shipping weights for different unit sizes.
Voltage, current, wire sizing, and protection ratings.
Details on compressor type, protection, and refrigerant type/amount.
Specifications for the condenser coil face area and fan motor.
List of available optional accessories for the unit.
Fan motor with ball bearings for improved lubrication and speed reduction.
Heater to keep lubricant warm, improving restart and preventing slugging.
Sound attenuation cover to reduce unit sound level.
Prevents compressor rapid recycling with a 5-minute delay.
Stops unit operation when evaporator reaches freeze-up conditions.
Removes contaminants from refrigerant for system protection.
Protects compressor from damage due to loss of outdoor airflow.
Stops and starts refrigerant liquid flow based on compressor operation.
Cycles outdoor fan motor to maintain head pressure at low temperatures.
Protects against indoor coil freeze-up and refrigerant loss.
Fan speed control based on condensing temperature.
Modulating flow control valve for evaporator response to superheat.
Continues indoor blower operation for additional cooling after compressor cycles off.
Bypasses low-pressure switch for start-up under low-load conditions.
Information on tested combinations and TDR function use.
Definitions for SEER, EER, TDR, TXV, and N/A.
Guidance on outdoor installation, airflow, and static pressure.
Minimum and maximum outdoor operating air temperatures.
Requirements for unit leveling and indoor/outdoor coil elevation.
Recommendations for long-line applications and buried tubing.
Specifies copper wire usage for electrical connections.
| Refrigerant | R-410A |
|---|---|
| Heating Capacity | Not Applicable |
| Heating Seasonal Performance Factor (HSPF) | Not Applicable |
| Operating Temperature (Heating) | Not Applicable |
| Stages | Single-stage |