the display. Duraon has no A or “P” indicaon. Each seng can be adjusted in 15-minute increments. The panel calculates the
end me and displays it automacally.
Set Filter Cycle 1:
1) Repeatedly press menu key unl FLTR appears.
2) Press up arrow and BEGN will be displayed.
3) Press up arrow again and then use up or down arrow to select filter cycle start me.
4) Press menu key twice to exit beginning me.
5) Press up menu to select run hours then press up arrow or down arrow to adjust hour.
6) Press menu key twice to exit.
Filter Cycle 2
It is possible to overlap Filter Cycle 1 and Filter Cycle 2, which will shorten overall filtraon by the overlap amount. Filter Cycle 2
is OFF by default.
Set Filter Cycle 2:
1) Repeatedly press menu unl FLTR2 appears
2) Press up arrow.
3) Press up arrow again to turn on.
4) Repeat step for seng filter 1.
Purge Cycles
In order to maintain sanitary condions, pump will purge water from plumbing by running briey at the beginning of each filter
cycle.
If Filter Cycle 1 is set for 24 hours, enabling Filter Cycle 2 will iniate a purge when Filter Cycle 2 is programmed to begin.
Preference
F/C (Temp Display)
Change the temperature between Fahrenheit and Celsius.
12/24 (Time Display)
Change the clock between 12 hr. and 24 hr. display.
RE-MIN-DERS (Reminders)
Turn the reminder messages (like “Clean Filter”) On or O.
CLN-UP (Cleanup)
Cleanup Cycle Duraon is not always enabled, so it may not appear. When it is available, set the length of me Pump will run
aer each use. 0-4 hours are available.
Ulies
A ulies menu selecon may be accessed and is intended for qualified service techs only.
GFCI Test
The Ground Fault Circuit Interrupter (GFCI) or Residual Current Detector (RCD) is an important safety device and is required
equipment on a hot tub installaon. (The GFCI Test Feature is not available on CE rated systems.)
Once the GFCI is tripped manually, reset the GFCI and the spa will operate normally from that point.
Warning: The end-user must be trained how to properly reset the GFCI or RCD. If freezing condions exist, the GFCI or RCD should
be reset immediately or spa damage could result.