Operaon Systems, Premium Series | ProView™ Control
51
The water is too hot – M029
The system has detected a spa water temp of 110°F (43.3°C) or more, and spa funcons are disabled. System will auto reset
when the spa water temp is below 108°F (42.2°C). Check for extended pump operaon or high ambient temp.
Heater-Related
The water flow is low – M016
There may not be enough water flow through the heater to carry the heat away from the heang element. Heater start up will
begin again aer about 1 min. See “Flow Related Checks” below.
The water flow has failed* – M017
There is not enough water flow through the heater to carry the heat away from the heang element and the heater has been
disabled. See “Flow Related Checks” below. Aer the problem has been resolved, you must press any buon to reset and begin
heater start up.
The heater may be dry* – M028
Possible dry heater, or not enough water in the heater to start it. The spa is shut down for 15 min. Press any buon to reset the
heater start-up. See “Flow Related Checks” below.
The heater is dry* – M027
There is not enough water in the heater to start it. The spa is shut down. Aer the problem has been resolved, you must clear the
message to restart heater start up. See “Flow Related Checks” below.
The heater is too hot* – M030
One of the water temp sensors has detected 118°f (47.8°C) in the heater and the spa is shut down. You must clear the message
when water is below 108°f (42.2°C). See “Flow Related Checks” below.
Flow-Related Checks
Check for low water level, sucon flow restricons, closed valves, trapped air, too many closed jets and pump prime. On some
systems, even when spa is shut down by an error condion, some equipment may occasionally turn on to connue monitoring
temperature or if freeze protecon is needed.
Sensor-Related
Sensors are out of sync – M015
The temperature sensors MAY be out of sync by 2°F or 3°F. Call for Service.
Sensors are out of sync -- Call for service* – M026
The temperature sensors ARE out of sync. The fault above has been established for at least 1 hour. Call for service.
Sensor A Fault, Senor B Fault – Sensor A: M031, Sensor B: M032
A temperature sensor or sensor circuit has failed. Call for Service.
Miscellaneous Messages
Communicaons error
The control panel is not receiving communicaon from the System. Call for Service.
System-Related
Program memory failure* – M022
At Power-Up, the system has failed the Program Checksum Test. This indicates a problem with the firmware (operaon
program) and requires a service call.