I accidentally connected the wires from the mobile power outlet to my vehicle in reverse and
the mobile power outlet will not work. Is the unit damaged?
It is dependent on testing the unit afterwards. There are no replaceable fuses in the mobile power
outlet nor is it recommended to open or service the unit. Reconnect the unit to the vehicle correctly
and try to operate the mobile power outlet. If the unit does not operate after reconnecting it, the
mobile power outlet suffered damage that is beyond repair.
How long can I use the mobile power outlet without the vehicle’s engine on?
The greater the rated amp hours of the vehicle battery, the longer the mobile power outlet will supply
power to the accessories. To determine the battery capacity, you will need to know the wattage of
the accessory the mobile power outlet will power. Add 15% to the wattage of the accessory due to
efficiency loss. Once you have determined the wattage, use the following formula to determine the
battery capacity in amp-hours and the operating time between charges. Use conservative estimates;
the number of amp-hours you expect to use should be 50% of the battery’s rated amp-hours. For this
example, we will use a 12-volt battery rated at 400 amp hours as follows:
2400 (example of total wattage) / 120 (AC volts) = 20 amps
400 (amp-hour rating of DC battery) / 10 (always use 10) = 40 amp-hours @ 120 volts AC
40 (amp-hours @ 120 volts AC) / 20 (amps) = 2 hours of operating time
DO NOT EXPOSE ANY PEAK ELECTRONIC DEVICES TO MOISTURE DURING STORAGE OR
OPERATION. USE PEAK ELECTONIC DEVICES IN WELL-VENTILATED AREAS.
IF YOUR QUESTION IS NOT ADDRESSED OR ANSWERED, PLEASE CONTACT PEAK
AUTOMOTIVE TECHNICAL SERVICES AT 1-800-477-5847 OR EMAIL TO:
owitech@oldworldind.com. THANK YOU FOR YOUR INQUIRY.
SPECIFICA
TIONS
1. Max output contin
uous power 1200 W
2. Max output peak surge 2400 W (0.4 sec)
3. North American Standard AC receptacles 2 on Inverter, 2 on Remote Outlet
4. Max output current 11.4 A
5. AC output voltage range 105 - 125 V
6. AC output frequency range 60 ± 3 Hz
7. DC input voltage range 11 - 15 V
8. Max no load current draw (12.8 V) 900 mA
9. Max input current consumption (12.8 V) 120 A at 1,200 W
10. Over voltage protection range 15.75 ± 0.75 V
11. Under voltage warning range 10.5 ± 0.5 V
12. Under voltage protection range 10.0 ± 0.5 V
13. Output overload protection range 1260 - 1560 W
14. Efficiency 80%
15. USB output 5 V, 2.1 A
16. Signal format Modified sine wave
17. Working temperature 14°F to 104°F (-10°C to 40°C)
18. Storage temperature -4°F to 185°F (-20°C to 85°C)
19. Storage air humidity 10%-90%
20. Remote outlet cord length 10 ft
21. DC fuse requirement for hard wire installation 200-amp ANL
22. Cable requirement @ 6 ft (1.8 m) #2 AWG
23. Cable requirement @ 10 ft (3.0 m)* 00 AWG
24. Dimensions (L x W x H) 10 x 5 x 3 in.
25. Weight 3.8 lb / 1.72 kg
* For cable requirements greater than 10 ft, consult a licensed electrician.