7.6. Waveform Saving Setups
The oscilloscope can save 4 waveforms, which can be displayed on the screen with the present waveform. The recalled
waveform saved in the memory cannot be adjusted.
The WAVE SAVE menu is described in the following list.
Function menu
Setup
Description
WAVE
A, B, C and D
Select the address for saving or recalling a waveform.
Save
Store the waveform into the selected address.
Show
ON
OFF
Close or start displaying the waveforms stored in address
A, B, C or D.
To save a waveform in address A, do the following:
1. Press the MENU key and the function menu appears at the right of the screen.
2. Press the MENU or MENU key to select the WAVE SAVE. Three options are displayed at the bottom of the
screen.
3. Press the F1 key to select the address A.
4. Press the F2 key to save the waveform in address A.
To display the saved waveform on the screen, do the following:
5. Press the F3 key to select ON for the address A- The waveform saved in address A will be displayed on the screen
in green color.
The display color is green, and the zero point of waveform, voltage and time is purple.
Now, you can see a screen that looks like the following Figure 42.
Figure 42: Waveform Saving