Meg Ohms
Bereich
Auf-
lösung
Genauig-
keit
Prüfstrom
Kurz-
schluß-
strom
0.125~4.000 MΩ
0.001 MΩ
+(2%+10)
1 mA (+ 10%) @
Last 125kΩ
≥1mA
4.001~40.00 MΩ
0.01 MΩ
+(2%+10)
40.01~400.0 MΩ
0.1 MΩ
+(4%+ 5)
400.1~4000 MΩ
1 MΩ
+(5%+ 5)
0.250~4.000 MΩ
0.001 MΩ
+(2%+10)
1 mA (+ 10%) @
Last 250kΩ
≥1mA
4.001~40.00 MΩ
0.01 MΩ
+(2%+10)
40.01~400.0 MΩ
0.1 MΩ
+(3%+ 5)
400.1~4000 MΩ
1 MΩ
+(4%+ 5)
0.500~4.000 MΩ
0.001 MΩ
+(2%+10)
1mA (+ 10 %) @
Last 500kΩ
≥1mA
4.001~40.00 MΩ
0.01 MΩ
+(2%+10)
40.01~400.0 MΩ
0.1 MΩ
+(2%+ 5)
400.1~4000 MΩ
1 MΩ
+(4%+ 5)
1.000~4.000 MΩ
0.001 MΩ
+(3%+10)
1mA (+ 10%) @
Last 1MΩ
≥1mA
4.001~40.00 MΩ
0.01 MΩ
+(2%+ 10)
40.01~400.0 MΩ
0.1 MΩ
+(2%+ 5)
400.1~4000 MΩ
1 MΩ
+(4%+ 5)