5.3. Inductance Measurement
To test the inductance, please follow the following procedure:
1. Set the rotary switch to LX measurement mode.
2. If the tested inductance value is unknown, use the
maximum measurement position and decrease the range
step by step until a satisfactory reading is obtained.
3. Insert the test clips into the corresponding Lx input
terminals.
4. Use the test clips to clip the inductance to carry out the
testing.
5. The measured value shows on the display.
REMARKS:
* When carrying out measurement at 2 mH, short circuit the
test clip first, then carrying out the measurement. The actual
correct reading is the measure reading minus the short
circuit reading.
* When testing a small value inductance, it is better to use the
small value jack.
* The Meter cannot check the quality of the inductance.
* When inductance measurement has been completed,
disconnect the connection between the testing clips and the
circuit under test and remove the testing clips away from the
input terminals of the Meter.