2.PlugtheUSBendintoaUSBpower 
4
outlet(1Aoutputminimum).
ThechargestatusLEDwillilluminate
solidredonceconnectedtopower.
See Image #4
3.Slidethelightintothechargerbase
aligningthetwoindicatinglines.
See Image #5
4.The7070Rincorporateswirelesscharging 
5
anddoesnotutilizedirectcontacts.
Oncealignedproperlythechargeindicator
willprovideaashingredLED.Oncecharge
iscompletedtheashingredLEDwill
changetosolidgreen.Thereisalso
a“FaultMode”providedthatindicates
an error, such as attempting to charge
withdisposableCR123batteriesinstalled.
5.Ifasecureattachmentisrequired,pushthelightbodybackintothechargerbaseandthe
lightwilllockintoplace.
Charger Mounting:
6
Thechargerbasecanbeattachedtoanysurfacewith(2)
size8orsize10screws(notincluded)throughthemounting
holeslocatedinthebackofthechargerbase.See Image #6.
Thechargerbasebackwillneedtobepulledawayfromthe
chargingcradletogainaccesstothemountingholes.
There is no need to fully discharge the 7070R before charging
thebattery.Chargingcanoccurwheneverrequiredandthe
7070Rcanbeleftindenitelyinthechargerhousingwithout
fearofover-charging.
Battery Level Indicator:
TheforwardswitchboothousesabuiltinbatterylevelindicatorLED.
Theindicatorisilluminatedwheneverthelightisactivated.Thebatterylevelinformation
isrepresentedasfollows:
See Image #7
7
Green = 100% - 75%
Yellow = 75% - 50%
Red = 50% - 25%
Flashing Red = 25% - 0%
Note:ThemainLED“blinks”every
5minutesoncethebatteryleveldrops
below25%.
Battery Replacement
WhentherechargeableLI-IONbattery
requiresreplacement,unscrewtheshroud
andpullthelampmodule/batterytrayfrom
thelightbodytoaccessthebattery.
Removetheusedbattery.Replacethe
usedbatterywithanewbattery.Replacementbatteriesareavailablewherever
PeliTorchsaresoldordirectlyfromPeliProductsCustomerService.
The7070Risabletouse(2)disposableCR123lithiumbatterieswiththeincludedbattery
tubeifrechargingisnotavailable.Note:CR123batteriesarenotabletobecharged.
NOTE:Pleaseact responsiblywhen disposingof theLI-IONBattery Stick.Thispart isrecyclable andshould notbe
disposedofinthemunicipalwastesystem.Pleasecheckwithyourlocalwastedisposalauthorityforinformation.
O-ring Maintenance
Checkcloselyforcuts,scratches,orotherwisedamagedO-ringormatinglenslipsurface.
RemoveanydirtorforeignmatterfromO-ringsealingsurfaces.Keepthreads,O-ringgroove
andinsidelipoflenslubricatedwithsiliconegrease.
Battery Safety Information
WARNING: HANDLE AND STORE BATTERIES PROPERLY TO AVOID INJURY
OR DAMAGE BATTERIES CAN BE DANGEROUS!
Mostbatteryissuesarisefromimproperhandlingofbatteries,andparticularlyfromtheuseofdamaged
orcounterfeitbatteries.Pleasereviewtheinformationbelowtoavoidseriousinjuryand/ordamageto
yourproperty.
Rechargeable Batteries
1.HazardouslocationsafetyapprovalsforexplosiveenvironmentsareonlyvalidforthePelibattery
packthatissuppliedwiththelight.
2.ForreplacementbatterypacksonlyusetheapprovedPelibatterypackforthemodelofthelightthat
youareusing.Theuseofotherbatterypackswillinvalidatethesafetyapproval.
3.Lightsshouldonlybechargedinanon-hazardouslocation.
4.LightsshouldonlybechargedusingthePelichargerbasethatissuppliedwiththelight.
5.Lightsshouldbechargedandoperatedbetweenthetemperaturesshown:ChargeTemperature:
-20°Cto50°C(-4°Fto122°F)
OperatingTemperature:-20°Cto50°C(-4°Fto122°F).
6.Donotchargewithalkalinebatteriesinstalledinthelight.Attemptingthiscancauseinternalgasor
heatgenerationresultinginventing,explosionorpossiblyre.
7.Deepdischarge of the rechargeable battery may cause batteries to vent potentiallydangerous
gassesandelectrolytes.
Always dispose of all batteries properly at an approved battery recycling center.