PP60 TROUBLE SHOOTING MANUAL
8-5-2013
NOT FEEDING PELLETS
HOME
HOME
PAGE 11
UNPLUG UNIT, CLEAN FIREPOT AND MAKE SURE IT IS
INSTALLED CORRECTLY, CLEAN FIREBOX AREA & CHIMNEY
PIPE, FILL HOPPER, PLUG UNIT BACK IN AND TURN UNIT ON.
IS THE VACUUM
SWITCH
CLOSING WHEN
THE EXHAUST
BLOWER COMES
ON?
SYSTEM IS
REPAIRED
CLOSE THE
HOPPER LID
YES
NO
IS THE FEED
MOTOR
TURNING?
MAKE THE REPAIR BY
EITHER CLEANING OR
REPLACING THE
COMPONENT OR
REPLACING THE
CONTROL BOARD.
IS THE HOPPER
SWITCH
CLOSING WHEN
THE LID IS
DOWN?
YES
NO
NO
YES
REPLACE THE
HOPPER SWITCH

Other manuals for Pelpro PP60

Related product manuals