PERFORMANCE OF PENBERTHY STANDARD INJECTORS
Suction Lift Operation
40 60 80 100 120 140
3 607080756555
8 5065757061.. ..
12 45 55 70 65 55 .. ..
16 36 50 65 60 45 .. ..
20 .. .. 45 60 53 .. ..
3 150 175 180 165 155 150
8 142 165 157 145 135 .. ..
12 135 155 135 133 120 .. ..
16 120 140 125 110 .. .. .. ..
20 .. .. 110 110 .. .. .. .. .. ..
3 300 350 350 310 295 280
8 290 300 300 270 250 230
12 260 270 265 240 220 .. ..
16 .. .. 240 235 215 .. .. .. ..
20 .. .. 220 210 .. .. .. .. .. ..
3 540 585 585 550 520 480
8 520 550 540 490 470 460
12 420 425 420 400 390 .. ..
16 .. .. 405 390 380 .. .. .. ..
20 .. .. 360 300 .. .. .. .. .. ..
3 780 940 950 915 840 800
8 760 900 870 780 720 705
12 730 750 750 630 570 .. ..
16 .. .. 580 555 525 .. .. .. ..
20 .. .. 440 440 .. .. .. .. .. ..
3 1440 1800 1800 1740 1620 1500
8 1300 1710 1710 1600 1460 1320
12 1200 1500 1500 1450 1400 .. ..
16 .. .. 1220 1200 1150 .. .. .. ..
20 .. .. 1020 1000 .. .. .. .. .. ..
3 2200 2520 2940 2880 2640 2500
8 2200 2520 2400 2160 1920 .. ..
12 2040 2280 2160 1920 .. .. .. ..
16 .. .. 1920 1800 1560 .. .. .. ..
20 .. .. 1560 1400 .. .. .. .. .. ..
3 3140 3600 4200 4100 3750 3550
8 3100 3600 3430 3100 2700 .. ..
12 2900 3250 3000 2700 .. .. .. ..
16 .. .. 2740 2550 2200 .. .. .. ..
20 .. .. 2200 2000 .. .. .. .. .. ..
DD-21
EE- 23
FF-23
GG-21
OO-21
AA-21
BB-21
CC-21
STEAM PRESSURES--PSIG
LIFT
IN FEET
SIZE
NO.
Capacities in Gallons per Hour at Various
Suction Lifts-74°F Water Temperature
Pressure Supply Operation
80 100 120 140 160 200 250
OO-21 80 95 100 115 115 110 105
AA-21 180 210 225 255 255 245 230
BB-21 350 405 440 490 490 475 445
CC-21 585 675 730 820 820 790 745
DD-21 950 1095 1190 1330 1330 1285 1205
EE-23 1800 2070 2250 2520 2520 2430 2285
FF-23 2940 3385 3675 4120 4120 3970 3735
GG-21 4200 4830 5250 5880 5880 5670 5335
SIZE
NO.
STEAM PRESSURES--PSIG
Cpacities in Gallons per Hour with 12 PSIG
Water Pressure Supply at 74°F Temperature
Capacities shown are maximum amount injector can pump
at steam pressures indicated. If flow exceeds amounts
shown, due t o excessive water supply pressure, valve in
water supply line can be regulated to provide correct flow.
Capacities are redu ced if injectors are required to handle
water at higher than normal temperature. When operating
with a 3 f t lift at the limiting temperature, for a given steam
pressure, capacities are reduced approximately as follows:
Water Temperature
90°F 100°F 110°F 120°F
Reduction in
capacity in %
10 12 15 20
Dimensions of Penberthy Standard
and High Pressure Injectors
ABCDEFG
OO 4 3/4 2 1 3/4 2 3/8 1 1/4 4 1/2 3/8
AA 5 7/8 2 3/8 2 3/8 2 5/8 1 1/4 5 1/8 1/2
BB 7 1/8 2 3/4 2 7/8 3 1/8 1 5/8 5 3/4 3/4
CC 8 1/8 3 3 5/8 3 3/8 1 7/8 6 5/8 1
DD 9 3/4 3 5/8 4 1/4 4 1/4 2 1/4 7 7/8 1 1/4
EE 13 1/4 4 3/4 5 3/8 4 3/4 3 9 5/8 1 1/2
FF 15 1/8 5 1/4 6 7/8 5 1/4 3 5/8 11 1/4 2
GG 17 5/8 5 7/8 8 1/2 6 5/8 4 1/2 14 1/2 2 1/2
DIMENSIONS IN INCHES
SIZE
NO.
6
NORTHEAST CONTROLS INCORPORATED
TEL: 201-419-6111 ext. 23 for Venturi Group
NORTHEAST CONTROLS INCORPORATED
TEL: 201-419-6111 ext. 23 for Venturi Group