ETi 400 Heater Fuel Gas Conversion Kit Installation Guide
ETi 400 Heater Fuel Gas Conversion Kit Installation Guide
8
Propane Conversion Kit Installation Instructions
(Continued)
7. Using T20 TORX Screwdriver remove the two screws from each igniter and
replace the igniters with the new ones provided. Discard the old igniters.
NOTE: DO NOT LOSE THE SCREWS! RE-USE IT ON NEW IGNITERS.
IMPORTANT: ONLY HAND TIGHT THE SCREWS!!! DO NOT OVER
TORQUE!!! SEE FIGURE 4.
Remove
igniter with
T20 Torx
screwdriver.
IMPORTANT:
ONLY HAND
TIGHT THE
SCREWS ON
THE NEW
IGNITERS!!!
8. Using Channel Locks to loosen the gas train at two gas orifice unions near the
blowers and replace the GAS ORIFICES inside with the new ones provided. See
Figure 5. Discard the old gas orifices. Be sure the gas orifices have o-rings and
are sitting flush inside the union. Tighten the unions using channel locks for a
good seal. See Figure 5.
Using Channel Locks
to loosen the two gas
orice unions and
remove the black pipe
gas train.
Figure 4.
Figure 5.