MagicFalls with LightCascade Technology LED Light Installation and User’s Guide MagicFalls with LightCascade Technology LED Light Installation and User’s Guide
V
IMPORTANT NOTICE:
THE MAGICFALLS
®
WITH LIGHTCASCADE TECHNOLOGY™
LIGHT IS A NON-SERVICEABLE LIGHT.
THE COMPLETE LIGHT ASSEMBLY MUST BE REPLACED.
IMPORTANT WARNING AND SAFETY INSTRUCTIONS
INSTALLERS AND INSPECTORS: THE MAGICFALLS WITH LIGHTCASCADE
TECHNOLOGY LIGHT AND PLASTIC HOUSING FORM A COMPLETE NON-METALLIC
LOW VOLTAGE LIGHTING SYSTEM. THIS CONFIGURATION DOES NOT REQUIRE
BONDING OR GROUNDING WHEN POWERED BY A LISTED 100 WATT OR 300 WATT
12 VAC TRANSFORMER AND INSTALLED IN COMPLIANCE WITH THE CURRENT
NATIONAL ELECTRIC CODE (NEC). UNBONDED LIGHTING NEC PROVISIONS.
WHEN THE UL LISTED NON-METALLIC MAGICFALLS WITH LIGHTCAS-
CADE TECHNOLOGY LOW VOLTAGE LIGHTS ARE USED WITH THE LIGHT
APPROVED NICHE, THE CURRENT NEC PROVIDES AN EXCEPTION TO
LUMINAIRE BONDING AND GROUNDING IN ARTICLE 680.6 AND 680.23
POOL WATER BONDING NEC PROVISIONS: FOR POOL WATER BONDING
REQUIRED BY NEC ARTICLE 680.26C, CONCRETE POOLS ARE CONSIDERED
CONDUCTIVE (REFER TO 680.26 (B)(1) DUE TO THE POROSITY OF CONCRETE
AND THE BONDING OF REBAR. NO ADDITIONAL BONDING IS REQUIRED.