Incorrect impeller rotation (three pha-
se motor) = check direction of rotation
Pump is not primed correctly = repeat
the "pump priming" procedure
For self-priming pumps only: the in-
ternal valve has not closed = gradually
close a valve until there is a visible in-
crease in pressure or flow. Then open
the valve gradually until the required
flow rate is reached.
Pump performance is unstable
Pump suction pressure too low or
cavitation = check the pump inlet
conditions
Suction pipe is partially obstructed
with impurities = clean the suction
pipe
Leak from suction pipe = repair or
replace suction pipe
air in suction pipe = bleed the suc-
tion pipe, repeat the "pump priming"
instructions
+For self-priming pumps only: The
differential pressure inside the pump
is too low = gradually close a valve
until delivery pressure stabilizes and
the noise level is reduced
The pump rotates in the opposite direc-
tion when shut down
Foot valve or check valve defective or
blocked in the open position = remove
and clean or replace the valves
Leak from suction pipe = remove and
repair suction pipe
DISASSEMBLY AND
DISPOSAL
Before any intervention on the
pump, disconnect the electrical
mains. Ensure that the electrical
power supply cannot be restored inadver-
tently.
Disconnect the pump electrically from
the system according to safety stan-
dards
Open the tap nearest to the pump to
decrease the system's pressure
Before disassembly, close the shut-
off valves on the delivery side, and if
present also close the shutoff valve on
the suction side.
Note the position of the filler
hole, which is also used as a
bleed point. Ensure that the liq-
uid on outlet cannot cause damage or
physical injury.
Loosen the filler cap to reduce the
pressure of the liquid remaining be-
tween the two valves
Remove the drain cap from the pump
body to completely empty the pump
This product or any part of the latter must
be disposed of in accordance with lo-
cal standards using the public or private
waste collection authorities as required.