EasyManua.ls Logo

Pentair MYERS MS50V10-R - Performance and Specifications; General Specifications; Performance Data; Electrical and Switch Data

Pentair MYERS MS50V10-R
28 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
6
MY999-R (06-20-20)
PERFORMANCE & SPECIFICATIONS
SPECIFICATIONS
Power supply required..............................................................................................................................115V, 60 HZ.
Liquid temp. range...................................................................................................................................32°F to 70°F(0°-21°C)
Individual branch circuit required (min.)...................................................................................................15 Amps
Discharge.................................................................................................................................................1-1/2” FNPT
NOTE:
Do not reduce size of discharge pipe or hose below 1-1/4” diameter. If discharge is too small, pump will overheat and fail prematurely.
ELECTRICAL & SWITCH SPECIFICATIONS
SERIES HP
MOTOR FULL
LOAD AMPS
INDIVIDUAL
BRANCH CIRCUIT
REQ. (AMPS)
AUTOMATIC SWITCH
TYPE
SWITCH SETTING IN INCHES WATER
LEVEL FOR:
ON OFF
MS50V10-R 1/2 4.1 15A 115 VAC Vertical Switch 7-1/2" 3"
PERFORMANCE
GPH (LPH) at total feet (m) of lift
SERIES HP
0'
(0.0m)
5'
(1.5m)
10'
(3m)
15'
(4.6M)
20'
(6.1M)
NO FLOW AT
HEIGHT SHOWN
BELOW IN FEET
(METERS)
Capacity Gallons(L)/Hour
MS50V10-R 1/2
4500
(17034)
3960
(15000)
3360
(12720)
2640
(9994)
1020
(3861)
25
(7.6)

Related product manuals