We recommend, for additional protection, the pump
to be supplied from socket outlet protected by a residual
current device - RCD (also known as an earth leakage
circuit breaker - ELCB) with a maximum rated residual
current of 30mA.
IM
H
RA
NG
E
HO
R
IZ
ONTAL
MUL
T
I
S
TA
GE
CENT
R
I
FU
GA
L
P
UM
PS
I
M
H
7
5
0 IMH1
1
00
IMH22
0
0

Questions and Answers

  • A
    Alexander SimmonsAug 12, 2025
    Why is my Pentair Water Pump operating but delivering no water?
    • A
      Angela HuberAug 12, 2025
      Several factors could be responsible. Ensure the pump is filled with water. Check that the suction head isn't too high and that the foot valve/strainer is sufficiently submerged. Also, inspect the suction pipe and joints for air leaks and make sure the suction pipe/strainer or non-return valves aren't clogged with debris. Finally, the pump itself may be clogged.
  • K
    krystal91Aug 19, 2025
    What to do if my Pentair ONGA IMH750 Water Pump does not operate and the motor doesn't run?
    • S
      Sabrina SmithAug 19, 2025
      First, verify the presence of electricity. Then, ensure the pump is connected properly. Finally, reset the circuit breaker if it has been activated.
  • D
    Donald HallAug 27, 2025
    How to fix reduced performance in my Pentair ONGA IMH750 Water Pump?
    • S
      Steven RichAug 27, 2025
      Reduced performance can occur for several reasons. Start by reducing the suction head and lengthening the suction pipe if the foot valve/strainer is only partially submerged. If these steps don't solve the issue, the pump shaft seal may be worn or damaged, requiring replacement of defective parts. Also, remove any debris and flush the pump with clean water in case the pump is partially blocked.
  • B
    Brian ChenSep 2, 2025
    What to do if Pentair ONGA IMH750 Water Pump hums and the thermal relays cut in and out?
    • R
      Robert SheppardSep 3, 2025
      This issue is typically caused by the pump being clogged by debris. Begin by cleaning the suction pipe and foot valve/strainer. Then, flush the pump with water, removing the priming and drain plugs. If the pump still won't start after several flushings, it will need to be dismantled and thoroughly cleaned.