85
Description Part Number
Start Capacitor,105 µF, 330v, 2 HP U17-1430-R
Start Capacitor, 208 µF, 330v, 3 HP U17-1428-R
Run Capacitor, 20 µF, 370v, 2 HP U17-1440-R
Run Capacitor, 45 µF, 370v, 3 HP U17-1443-R
Main Overload Protector, 2 HP U17-1319-R
Main Overload Protector, 3 HP U17-1322-R
Start Overload Protector, 2 HP U17-1320-R
Start Overload Protector, 3 HP U17-1323-R
Relay - 2 HP U17-1592-R
Relay - 3 HP U17-1432-R
Magnetic Contactor P17-954-R
Description Part Number
Start Capacitor,105 µF, 330v, 2 HP U17-1430-R
Start Capacitor, 208 µF, 330v, 3 HP U17-1428-R
Run Capacitor, 20 µF, 370v, 2 HP U17-1440-R
Run Capacitor, 45 µF, 370v, 3 HP U17-1443-R
Main Overload Protector, 2 HP U17-1319-R
Main Overload Protector, 3 HP U17-1322-R
Start Overload Protector, 2 HP U17-1320-R
Start Overload Protector, 3 HP U17-1323-R
Relay - 2 HP U17-1592-R
Relay - 3 HP U17-1432-R
SECTION 11: Submersible Motor Controls
Start
Capacitor
Run
Capacitor
BL
Installation wiring
should be installed
into the top of the
terminal block
3
3
2 and 3 HP Standard
Models SMC-CR2021 and SMC-CR3021
Attach Installation
wiring to top of
terminal block
2 and 3 HP Plus
Models SMC-CRP2021 and SMC-CRP3021
60 Hz.
SMC Panels
60 Hz