    Why is the GFCI/breaker tripping with my Pentair SMART UV EU18-U Laboratory Equipment?
    • W
      William HallAug 12, 2025
      If the GFCI/breaker is tripping, immediately disconnect power to the SMART UV[®]. Turn off the pump at the circuit breaker and be sure all flow to the unit has been stopped. Check for water or moisture inside the quartz sleeve. It is also possible that multiple appliances connected to a circuit protected by one GFCI create the potential for cumulative leakage current resulting in a tripped GFCI.
  • Z
    zadamsAug 21, 2025
    What to do if my pond is still green after a week of Pentair SMART UV EU18-U UV operation?
    • L
      Lisa BrownAug 21, 2025
      If your pond is still green after a week, ensure the UV lamp is lit by utilizing the safe viewing port. A dirty quartz sleeve can reduce the UV system's performance. Double check the unit’s flow rate and compare to the flow rate chart for your specific UV model.
  • K
    kgoodAug 30, 2025
    How to fix a paper towel leak test that indicates a leak in Pentair Laboratory Equipment?
    • J
      Jessica HollandAug 30, 2025
      If a paper towel leak test indicates a leak, turn off the pump at the circuit breaker and be sure all flow to the unit has been stopped. Ensure there are no cracks or breakages in the Quartz Sleeve, that the Quartz Sleeve Gasket is properly installed, and that the Quartz Sleeve Retaining Nut has been tightened down completely. Repeat the Mandatory Leak Test until there are no indications of a leak.

Pentair SMART UV EU18-U Specifications

General IconGeneral
ModelSMART UV EU18-U
CategoryLaboratory Equipment
ApplicationWater Disinfection
UV Dose30 mJ/cm²
TypeUV Sterilizer
Lamp Life9000 hours
Lamp TypeLow pressure UV lamp
CertificationCE
Voltage100-240V / 50-60 Hz
Maximum Operating Pressure125 PSI

Related product manuals