38
GB
i
12 V DC terminal screws
j
Cable guide
k
Side and lower sensor openings
Technical data
Gas alarm:
Power supply: 12 Volt DC (±10%)
mains adapter (deliv-
ered with the gas
alarm) or on-board
power supply system
Current consumption: max. 150 mA
Gas sensor: hot-wire method
Sensitivity/alarm
threshold: corresponds to a con
-
centration of approx.
12 % of the relevant
lower explosive limit
Propane: 0.2 %
Butane: 0.17 %
Methane
(town gas/natural gas): 0.53 %
Alarm signal: loud high-frequency
tone
Volume: 85 dB(A) 3m
Operating temperature: -10 °C to +40 °C
Relative air humidity: max. 95 %
Material: ABS plastic
Dimensions: 35 x 85 x 85 m (h x w x l)
Weight: approx. 100 g
Protection class: III
Mains adapter (delivered with the gas
alarm):
Power supply: 230 V ~ 50 HZ
Current consumption: 60 mA
Current output: 12 Volt DC
max. 300 mA
Connecting cable length: approx. 2 m
Safety instructions
The following instructions are for your own
safety and satisfaction when operating the GA50
gas alarm. Please note that non-compliance
with these safety instructions can lead to a
serious risk of accident.
Explanation of the symbols and terms
used:
c Danger! Failure to observe this instruction
endangers life and health.
m
Caution! Failure to observe this instruction
poses a risk to property.
c Danger!
Do not leave small children unsupervised
with the packaging material. Danger of
suffocation.
Do not leave children unsupervised with
the device. Danger to life and risk of injury.
Do not damage any gas, electricity or