Troubleshooting
Fault Cause Remedy
The gas alarm responds
when there is no actual
gas leak.
The gas alarm will respond to
fumes from cleaning agents,
paint, lacquers, sprays, cooking
fumes, tobacco smoke and
smoke from candles.
Remove the source of the
fumes.
The gas alarm fails the
function test.
The service life of the gas
alarm expires after approx. 5
years of operation.
Replace the gas alarm.
The gas alarm does not
work.
The power supply is faulty. Make sure that the power
supply is free of faults.
FAULT-LED flashes
See section on
“Fault display”
See section on
“Fault display”