Timer, Counter, Tachometer KC-LCDC-48-2R-24VDC
Technical data
General specifications
Pre-selection  2-fold
Data storage  > 10 years, EEPROM
Programming  keypad-driven menu
Functional safety related parameters
MTTF
d
  410 a
Mission Time (T
M
) 10 a
Diagnostic Coverage (DC)  0 %
Indicators/operating means
Ty p e   2-line, 2 x 6-digit LC display with leading sign 
Multicolor, backlit
Display value  digit height 9 mm
Pre-selection  digit height 7 mm
Key interlock  via "high" potential at "LOCK" input
Decimal point  0 to max 5 fractional digits
Scale factor  0.0001 ... 99.9999
Reset  manually or external
Electrical specifications
Fusing  10 … 30 V DC: T 0.2 A
Operating voltage  U
B
10 ... 30 V DC
Power consumption  P
0
max. 1.5 W
Input
Connection  Counter inputs: A and B 
Control/reset inputs: LOCK, RESET, GATE, MPI
Signal voltage   
High  0.6 x U
e
  ... 30 V DC
Low  0 ... 0.2 x Ue
Counting frequency  30 Hz / 55 kHz
Minimum pulse duration  Control/reset inputs: 10 ms / 1 ms
Impedance  5 kOhm
Count modes   
Pulse counter  Counting with counting direction (cnt.dir),
difference counting (up.dn),
up/down counting (quad), 
Cumulative counting (up.up),
up/down counting x 2 (quad 2),
up/down counting x 4 (quad 4),
additional functions for counter input A and counter input B:
A/B, (A-B)/A x 100%
Frequency counter  functions for input A and input B:
 A, A-B, A+B quad, A/B, (A-B)/A x 100 %
Timer  Time measurement via GATE input (FrErun),
counter input A: Start, counter input B: Stop (InpA.InpB.),
counter input B: Start/Stop (InpB.InpB.), 
time measuring via RESET input (auto)
Output
Relay  changeover contact , Make contact
Switching voltage  max. 250 V AC / 110 V DC
Switching current  max. 3 A AC/DC, min. 30 mA DC,
Switching power  max. 750 VA / 90 W
Sensor supply  connected power supply is looped through,
max. 80 mA
Output I  Relay with make contact, NC or NO progr.
Mechanical life  2x10
7
 switching cycles
Electrical life  1 x 10
5
 switching cycles at 3 A
Output II  Relay with changeover contact
Mechanical life  2 x 10
7
 switching cycles
Electrical life  5x10
4
 cycles at 3 A
Response time  Relay: approx. 7 ms 
Frequency counter: 100/600 ms
Ambient conditions
Ambient temperature  -20 ... 65 °C (-4 ... 149 °F)
Storage temperature  -25 ... 75 °C (-13 ... 167 °F)
Relative humidity  ≤ 93 % at 40 °C (noncondensing)
Altitude  0 ... 2000 m
Mechanical specifications
Degree of protection  IP65 (front)
Mass approx. 138 g
Dimensions  48 mm x 48 mm x 109.8 mm
Compliance with standards and directi-
ves
Directive conformity   
EMC Directive 2004/108/EC  EN 61000-6-2:2005
Standard conformity   
Emitted interference  DIN EN 55011:2009, Class B
Model Number
KC-LCDC-48-2R-24VDC
LCD batch controller with 2 relay outputs 
and 24 V
DC
 supply voltage
Features
• Counter/Timer/Tachometer
• Adding/subtracting via 2 separate in-
puts
• Batch controller with 2 pre-selections
• Easy-to-read backlit 2-line LCD dis-
play with icons for the displayed pre-
selection and the status of both 
outputs
• Multicolor display
• Display range and preselection range 
from -999999 up to 999999
Overflow will be evaluated correctly 
up to 1 decade
• PNP and NPN sensors can be con-
nected
• Degree of protection IP65 (front only)