Thermal Imaging Camera Manual
°C
°C °C
±2% or ±2°C(±2% or ±4)
±40°C°C
°C
±50°C
1. Slide the battery cover open for inserting new
batteries into IR0002
2.Ensure polarity of batteries inserted are correct
3.Cloce the battery cover.
3-Menus
°C
°C
IR0002
1. Introduction
IR0002 is a thermal Imaging Camera combining
functions of surface temperature measurement
and real-time thermal imaging.
Normal Infrared thermometer measures each
temperature points one by one, this instrument
help reduce measurement time by identifying
potential problems through thermal image on
the color screen, users can quickly locate the
c e n t r a l p o i n t t o m e a s u r e c u r s o r a n d
temperature. This product is equipped with a
vision camera to improve recognition, it can turn
thermal i m a g e into visible ima g e base on
practical requirements.
Thermal image and visible image can be stored
in the memory card, captured images can be
stored in PC for report or for printing.
This product is most suitable for electrician;
maintenance personnel and house owners for
identifying potential problem areas.
T he f o l l o w i ng f u n c t i o n s h e l p t o i m pr o ve
accuracy and usability of this product:
Adjustable radiation coefcient and reection
background compensation, it helps to improve
accuracy of measuring semi-reective surfaces.
● The marking of hot spot and cold spot can help
user to locate the hottest and coldest area of
thermal imaging temperature.
● Choice of different color palettes.
2. Safety Precautions
Pl e as e c are ful ly re a d thi s m an u al be for e
operation to ensure accurate measurements.
Please strictly follow this manual to operate this
product, in case of any problems due to
operational errors, maintenance charge may be
incurred.
Do not use this product under explosive; damp
or corrosive environment.
If the product is damaged, broken or has just
been repaired, the measurement results might
be inaccurate.
Please refer to radiation coefcient to get the
a c c u r a t e t e m p e r a t u r e m e a s u r e m e n t s .
Measured temperature might be lower than
a c t u a l te mp e r a tu re b e c a u s e of re e c t i v e
s u r f a c e a nd th es e s u r fa ce s m i g h t c au se
potential burning hazard to users.
4.Structure
6.Menu Description
5. Battery Installation
Figure 2 Structure of Product
Start up the instrument and then put the head of
sensor close to the worktop. Press “up” key for 5
seconds to eliminate the noise.
Press “image capturing key for 5 seconds to
turn on LED light to assist working of visible
camera if needed.
7. Focal distance
8. Elimination of noise
9. LED light
Press Start-up key for 5 seconds to power up
the instrument.
Press menu key for 1 second to enter mode
setting of basic functions.
The LCD shows 5 function setting options in 1
screen, press up or down key to scroll
through the menus and select the function for
adjustment by the yellow option box.
Press “selectkey and select menuoption and
edit the value. Press up or down key to edit
the value, . After adjustment, conrm the new
value and press menu key to exit the edit
mode.
10. Product Operation
0002 is of fixed-focal thermal Imaging Camera
design and applicable distance is 50cm (20min).
IR
3.Product Specications

Other manuals for Perfect Prime IR0002

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Perfect Prime IR0002 and is the answer not in the manual?

Perfect Prime IR0002 Specifications

General IconGeneral
BrandPerfect Prime
ModelIR0002
CategoryThermal cameras
LanguageEnglish

Related product manuals