COMPRESSOR
MODEL HP
MOTOR
TYPE
START
WINDING
RESISTANCE
Ω AT 77°F
(+/-8%)
RUN
WINDING
RESISTANCE
Ω AT 77°F
(+/-8%)
LOCKED
ROTOR
AMPERAGE
(LRA)
STARTING
DEVICE
MOTOR
PROTECTION
CAPACITOR
(Run/Start)
(uF/VAC Minimum)
EM30HHR 1/10 RSIR 20.9 5.5 14.5
Current
Relay
4TM575MFBYY-
53
N/A
EM65HHC 1/6+ RSCR 3.7 3.2 15.0 PTC
4TM427NFBYY-
53
Run (20/170)
EM20HSC 1/10 RSCR 13.2 9.3 5.2 TSD2-115V
4TM189KFBYY-
53
Run (5/175)
EM3D50HLT 1/5 RSCR 5.9 5.4 8.0
TSD2-
115V0.6
4TM302KFBYY-
53
Run (15/200 or
12/200)
VEGY3H 1/10 BPM 16.1 16.1 2.1 Inverter Inverter N/A
VEGY7H 1/4 BPM 6.4 6.4 3.3 Inverter Inverter N/A
Return to Table of Contents
Residential Refrigeration
and Front Venting Commercial Refrigeration
Service Manual
Compressors
Table 7-2. Compressor Data
Refrigeration System Repair Instructions Page 7-8