11 - 13
Adjustment
● Set needle bar at 2 mm past b.d.c. (use screw clamp and needle-rise gauge).
● Set hook point at "needle centre" and tighten screws 4.
● If necessary, readjust needle bar according to Requirement 2.
● Remove hook base and turn eccentric 7 (screw 8) according to Requirement 3.
On the PFAFF 1526, also loosen screws 1, 2, 3 and 4 on the second hook and
carry out the adjustments as described.