Improper
Feeding
Cause
Feed
dog
set
too
low
,po
that
it
does
not
rise
suffi
ciently
above
needle
plate
eve!.
Remedy
Adjust
position
of
feed
dog
so
that
it
shows
a
full
tooth
above
the
needle
plate.
Accumulations
of
packed
Take
off
needle
plate
and
lint
between
tooth
rows,
remove
lint
with
a
stiletto.
Insufficient
pressure
of
the
presser
foot
on
the
ma
terial.
Screw
in
pressure
regulat
ing
screw
V.
(Chapter
1
1).
if
machine
does
not
feed
at
all,
check
whether
feed
dog
has
been
disengaged
or
stitch
length
lever
set
at
zero.