34
Phantom Miro C110 Camera Manual
• Sensor cleaning should only be attempted by
experienced imaging professionals.
• Use a small, but powerful flashlight to look at the
sensor and filter, it’s easier to spot the dust.
• The OLPF assembly is removable and located in front
of the sensor. Once the lens mount is uninstalled the
OLPF can be easily removed (2 screws) for cleaning
(if applicable).
• Sensor cleaning must be done in a clean and con-
trolled environment.
• Always have a forced-air bulb style blower and a
clean sensor cloth handy for more serious dirt.
• Sensor cleaning solution (like Eclipse) should only be
used if absolutely necessary, and applied with a soft
wipe intended for sensor cleaning.
• Cotton swabs aren’t a good idea, unless they are
wrapped in a sensor wipe material. They leave
behind more than they remove.
• Never use your finger to get a speck of dust off, it’s
going to make things much worse.
• Never blow on the sensor or OLPF.
• Never put sharp objects near the surface of the OLPF
or sensor.
• Always keep the Phantom body cap on the camera
when there is no lens attached.
Sensor & OLPF Cleaning
Technical Tips
maintenance