Philco KG7 - 97+ AFUE iQ Drive Modulating Furnace; iQ Drive Modulating Heating Operation; iSEER ECM Motor Benefit; iQ Drive Controller & Accessories

Philco KG7
16 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Davies Supply Group Ltd.
Calgary (800) 661-1346 Lethbridge (877) 595-7707 Saskatoon (877) 355-3377
(403) 244-2161 (403) 381-7707 (306) 933-2433
Furnaces
A44
22/11/13
 Customizable programming options for every day, weekdays, weekends or individual days
 On-board diagnostics alert when service or maintenance is needed
 Smart recovery gradually adjusts indoor temperatures for greater comfort
 Senses humidity and has a dehumidification mode that removes moisture quickly
 Communicates to various components within the iQ Drive® System and serves as
the main controller for an iQ Zone® System
 Auto changeover automatically switches the thermostat from heating to cooling
 No batteries required, settings are stored internally in the event of a power failure
 Two color backlight for easy viewing
 Energy saving features are customizable (temperature setbacks, heat pump/electric
heat or furnace changeover)
Description Part Number
iQ Drive® Controller - Complete System Monitor & Controller
920621F
Individually Shielded Wire, 30m (100')
2 Pair, 4 Conductor, 22 AWG Stranded (7x30) TC Conductors, 300V RMS 60ºC
B8723
Optional Outdoor Sensor
920938
Accessories
iQ Drive® Controller & Accessories
IMPORTANT
The iQ Drive
®
Furnace must
be controlled by the iQ Drive
®
Controller. This Controller
requires 18-22 gauge stranded
wire with a grounded shield
when connecting to furnace.
PVC & CPVC Fittings
97+ AFUE iQ Drive® Modulating Gas Furnace (Ultra High Efficiency)
 iQ Drive® Modulating Heating Operation Includes:
- Modulating gas valve from 100% to 50% input in 5% increments
- Time proportioning modulation down to 15%
- Variable speed inducer and blower
 iQ Drive® thermostat provides modulation down to 15% and is required for furnace
operation
 iSEER energy efficient brushless DC (ECM) motor gives up to 1 SEER point
efficiency gain in cooling
Input Btuh HP -Speed-FLA R410 Coil Model Number Part Number
Fully Modulating, Variable Speed Upflow / Horizontal
60,000 1/2 - Variable - 6.2
C7B(A,H)M01824(C,U)B
C7B(A,H)M03036(C,U)B
C7B(A,H)M03642(C,U)B
FG7MQ060DVB
904743F
80,000 3/4 - Variable - 8.7
C7B(A,H)M030(C,U)C
C7B(A,H)M03648(C,U)C
C7BAM048(C,U)C
C7BHM04860CC
FG7MQ080DVC
904744F
100,000 3/4 - Variable - 8.7
C7B(A,H)M030(C,U)C
C7B(A,H)M03648(C,U)C
C7BAM048(C,U)C
C7BHM04860CC
FG7MQ100DVC
904745F
120,000 1.0 - Variable - 11.7
C7B(A,H)M042(C,U)D
C7BAM048(C,U)D
C7B(A,H)M04860CD
FG7MQ120DVD
904746F
R410 Coil:
(A,H) A=Vertical, H=Horizontal
(C,U) C=Cased, U=Uncased