Battery-Monitor BLS
REV 1A – APR 2019 - Software Version 1A page 18
Measuring range I, shunt -600 - + 600A, resolution 10mV, accuracy 0.5%
Measuring range T (external sensor) -15 - 60 ° C, resolution 1K, accuracy 1K
Dimensions monitor L 105 x W 75 x D 40 mm
Dimensions Shunt L 118 x W 40 x H 65 mm
Connections shunt bolt M8
9. Declaration of conformity
This device complies with the requirements of the EU directives:
2014/30 / EC "Electromagnetic compatibility"
Immunity EN 61000-6-1
Emitted interference EN 61000-6-3
The conformity of the device with the o.g. The directive is confirmed by the CE mark.
10. Disposal instructions
When disposing of this device, observe the applicable local regulations and use the
collection services / points for waste electrical and electronic equipment.