5-4 A17FXUH EA
[32HFL5763L/F7]
General Note: “CBA” is abbreviation for
“Circuit Board Assembly.
Note: Electrical adjustments are required after
replacing circuit components and certain
mechanical parts. It is important to perform
these adjustments only after all repairs and
replacements have been completed.
Also, do not attempt these adjustments unless
the proper equipment is available.
Test Equipment Required
1. Set up remote control unit
2. Color Analyzer,
CA-310 (KONICA MINOLTA Luminance meter) or
measuring instrument as good as CA-310.
How to set up the service mode with
Set Up Remote Control Unit
1. Turn the power on.
2. Press [0], [6], [2], [5], [9], [6] and [RECALL/INFO]
buttons on the set up remote control unit in this
order.
3. Select “Quality” - “BE Factory Mode” and press the
[OK] button. The following screen appears.
Code:
Pic code:
Option code:
MIPS:
Press "POWER" key to exit.
*******-**-**-****-**
**********-***-*-**
***-***-***-***
Push 0 key
Safety: Safety_Non Total Watch Time:
Lightsensor:
*****
****
"
*
" differs depending on the models.