Loading...
10-23
TOOL NO.
1 2 3 4 5 6 7 8 9 10
C7A3 A3
C7A3/A3
C7A3 A3
/
GREEN
/
RED
/
ORANGE
BA17F4F0103 1 C
C7A3 A3
BA17F4F0103 1
D
2
3
ABC DEF
COLD
HOT
1
BC1301
BC1930
BC1931
C1930
C1990
C1905
C1906
C1104
C1106
C1108
C1110
C1112
C1114
CN1900
CN1901
CN1003
CN1001
D1700
D1702
D1704
D1706
D1932
D1933
D1960
D1961
D1972
D1973
D1200
D1201
D1202
D199
0
D1991
D1992
D1300
D1301
D1701
D1703
D1705
D1707
D1930
D1931
D1970
D1971
D1934
D1994
C1700C1701
C1993
C1994
C1910
C1982
C1983
C1206
C1302
C1304
IC1930
IC1931
VSEN
J1058
PROT
J1059
J1081
DUTY
GND
J1092
REG 7.5V
J1095
GND
J1103
BL-SWJ1107
J1108
J1109
GND
GND
J1120
JS1200
GND
J1003
GND
J1004
J1093
J1055
VS2
J1061
VSENJ1062
DC12V
J1072
BL-SW
J1097
+24V
J1100
GND
J1005
SW2
J1010
SW2
J1011
SW2
J1012
SW2
J1013
SW1J1014
SW1J1015
BST2
J1063
PROTECT3
J1105
STBJ1070
J1082
J1101
SW2
J1024
SW2J1025
J1032
PROT6
GND
J1044
PROT
J1068
GND
J1079
GND
J1084
GND
J1088
GND
J1099
GND
J1104
J1002
REG 7.5V
NH1
J1074
LN1
J1076
GND
J1077
J1083
PROT6
J1048
VS6
J1054
+24V
J1090
J1075
VS4
J1067
BL-SW
J1096
GND
J1026
GND
J1028
J1069
SW1
J1071
VSEN
J1080
+24V
J1085
PROTECT3
J1098
SW1
J1047
J1033
J1034
PROT5
J1035
PROT4
J1036
GNDJ1045
J1078
J1089
GND
J1051
+24VJ1064
+24VJ1065
+24VJ1066
J1073
GND
J1037
REG 7.5V
J1091
J1060
LN1J1039
NH1J1040
LN2J1041
NH2J1042
SW2J1038
PROT3
PROT2
PROT1
J1046
J1049
J1050
J1053
J1056
Q1931
Q1932
Q1930
R1103
R1106
R1115
R1118
R1127
R1130
R1143
R1145
R1146
R1147
R1148
R1150
R1930
R1931
R1932
R1933
R1934
R1935
R1936
R1938
R1939
R1949
R1967
R1970
R1305
R1937
T1950
GND
J1027
LN2J1030
NH2J1031
J1001
J1110
PROT5
PROT4
J1111
J1112
J1113
PROT
J1087
FAILJ1086
D1203
BA17F4F0103 1 A
BL-ADJ
J1102
R1704
R1709
J1020
J1021
PROT5
J1022
PROT4
J1023
J1006
PROT3
PROT2
J1007
J1008
J1009
CN1100
CN1101
CN1102
T1100
T1101
T1102
4
VOL
UP
VOL
DOWN
MENU
CH
UP
CH
DOWN
POWER
VOL
DOWN
VOL
UP
MENU
CH
DOWN
CH
UP
EJECT
STOP
PLAY
POWER
PATTERN
AGING
C108
C151
D107
D151
J101
R108
R109
R111
R112
R113
R114
R115
R151
R152
R153
R154
R155
R156
SW101B
SW154
SW155
SW103B
SW104B
SW105B
SW106B
SW107B
SW151
SW101A
SW152SW153
SW103A
SW104A
SW105ASW106A
SW107A
CL103B
BA17F4F0103 1 B
STD BY
DVDPOWER
GND
C113
J102
D104
D105
D106
R123
R124
R127
R128
RS102
CL103C
CL101B
STB BY
D108
D109
C101
D101
R101
RS101
CL103A
CL102B
1
2
10
11
1
2
14
15
BA17F4F01031
Inverter CBA, Function CBA & IR Sensor CBA Top View
NOTE:
The voltage for parts in hot circuit is measured using
hot GND as a common terminal.
Because a hot chassis ground is present in the power supply
circuit, an isolation transformer must be used when repairing.
Also, in order to have the ability to increase the input slowly,
when troubleshooting this type of power supply circuit,
a variable isolation transformer is required.