10-21
Digital Main CBA Top View [TYPE B]
R611
C605
C606
C607
C611
C614
C619
C620
D601
D602
D603
D604
D607
D608B
L601
L602
HOT
R601
CN601
C604
C616
C617
C618
C652
C657
F601
SA601
BOND
BOND
T 2.5A L/250V
RISK OF FIRE-
REPLACE FUSE AS MARKED
BLACK
LIVE
CAUTION -
WHITE
NEUTRAL
C3828
C3829
D3806
R3805
R3807
R3808
C3830
IC3801
C3831
C3836
R3815
D650B
D651A
D651B
D652A
D652B
R650
R3868
D655A
C653
C658
C662
D659A
D659B
C1001
D658
L3603
L3802
L3803
L3804
CN3801
C3801C3802C3803
C3804
Q3801
C3811
C3812
C3813C3814
C3815
C3816
C3817
C3818
C3819
C3821
C3823
C3824
C3825
C650A
C3827
COLD
1
14
15
28
1
4
SP
C612A
R603
R604
R606
R607
R608
R609
R612
R613
R614
R615
R616 R617
R621
R623
C602
C603
C608
C609
D653A
D653B
C610
R651
D654B
C621
C622
C623
D655B
C655
C656
R694
C660
C663
C664
C665
D605
D606
C666
D609
D610
IC601
D621
D623
T601
D656
Q601
Q602
BC601
Q621
R3605
IC3604
C3638
R3610
C3639
R3614
R3615
R3616
R3618
C3643
TU9001
R3622
C9023
C3652
IC9001
R3643
L3913
TP3901
TP3902
R652
R654
R655
R656
R657
R658
R659
R660
R661
R667
R668
R669
R675
C654
C667
C669
C3905
C3906
Q1001
C3910
X9001
D3901
C3926C3927
D657
D3904
R1002
R1005
D661
L3602
D660A
R3936
R3937
R3938
C3602
C3603
C3604
C3606
C3607
C3609
C3612
C3615
R3206
C3616
R3207
C3618
CN9002
C3620
C3621
C3623
R3602
R3604
D3608
D3609
Q650
IC3601
Q653
C9001
C9002
C9003
C9004
C9005
C9006
C9007C9008
C9009
C9010
C9011
C9012
C9013
C9014
C9015
C9016
C9017
C9018
C9019
C9020
C9021C9022
L9001
L9002
L9003
L9004
L9005
L9006
L9007
R9001
R9002
R9003
R9004
R9005
4
5
1
8
3
1
1
C3634
L3108
IC3605
Q3631
C3635
C3636
Q3632
C3637
R3617
R3619
R3624
R3625
R3626
TP3112
R3635
R3636
R3637
R3638
R3646
C3686
C3687
C3104
C3105
C668
C3118
C3119
C3125
C3126
C3139
Q1002
C1007
C3141
C3142
C3143
C3144
C3145
R3124
R3125
R3127
C3150
R1001
R3136
R1003
R1004
C3168
C3169
R3144
C3172
C3173
C3174
R3151
R3152
R3157
R3158
R3163
R3176
JK3002
R3181
R3187
R3190
R3198
X3101
C3601
C3605
C3608
R3200
C3610
C3611
C3613
R3203
C3614
R3205
R3208
R3209
C3622
C3624
C3625
C3626
C3628
R3606
IC3602
C3632
C3633
IC3603
8
14
5
46
47
1
3
1
3
4
6
D3805
C3832
R3811
R3812
R3047
R3048
R3248
R3825
R3249
R3093
R3863
R3094
R3095
Q3103
R3102
R3103
R3104
R3107
C1002
R3112
R3116
L3201
R3130
R3133
C3170
R3149
C3171
C3175
L3801
R3153
R3160
R3161
R3165
R3170
R3188
R3189
R3197
R3199
C3000
CN3013
Q3007
C3205
C3207
C3208
C3209
C3211
C3212
C3213
C3214
C3215
CN3803
R3002
R3004
D3204
IC3201
R3217
D3606
C3057
BA5G27G0201 1
78
79
151
LVDS
4
VCOM
58
C1118
C3253
C3254
C1120
C1121
C3255
C1122
C1123
C1124
D1108
R3044
R3045
C3073
R3241
R3822
R3089
R3092
CN3101
C3101
C3106
Q3104
C3110
C3113
C3116
Q3501
Q3502
R3101
R3105
R3106
C1003
C1004
C1005
R3111
D3501
D3502
R3501
R3119
R3502
R3503
R3137
C3554
C3558
R3159
R3162
R3551
R3552
R3553
R3555
R3556
R3557
R3558
R3559
R3560
R3182
R3183
R3184
R3185
R3186
R3194
R3395
R3396
CN3010
Q3010
CN1101
IC3006
IC3009
R3219
R3601
C1114
C1115
C1116
C1117
19
IR
124
125
1
4
1
UART
B/L
14
4
21
3
R3420
R3055
R3058
C3852
R3063
R3066
R3275
C3701
C3702
C3703
Q3701
C3706
C3707
C3708
C3709
IC3101
C3713
C3714
C3718
C3719 C3720
R3706
R3707
R3708
R3709
R3710
R3712
R3713
R3714
R3716
JK3003JK3004
Q3001
C3005
Q3008
C3012
C3404
C3023
R3001
R3010
R3017
R3018
R3019
R3401
R3406
R3407
R3022
R3023
WHITE
RED
RED
ORANGE
WHITE
ORANGE
156
1
91
19
1
D3052
C3851
C3857
C3858
R3851
R3852
R3853
R3854
R3855
R3856
IC3851
R3480
JK3701
JK3703
C3705
C3327
C3710
D3701
D3702
C3348
CN3009
R3020
IC3019
R3021
C3246
RED BLUE
BLUE
GREEN
GREENRED
14
41
1
3
D1101
D1102
IC1101
R1110
R1111
R1112
R1113
R1118
R1120
R1121
R1128
R1129
R1130
R1131
C1006
L1102
Q1101
C1105
Q1102
C1106
C1107
C1109
C1110
C1111
C1112
C1113
16
18
9
C1119
R1115
L1101
L1103
C1101
C1102
C1103
Q1103
C1108
D650A
1
4
5
8
58
6
4
1
19
4
5
Because a hot chassis ground is present in the power supply
circuit, an isolation transformer must be used when repairing.
Also, in order to have the ability to increase the input slowly,
when troubleshooting this type of power supply circuit,
a variable isolation transformer is required.
CAUTION !
Fixed voltage (or Auto voltage selectable) power supply circuit is used in this unit.
If Main Fuse (F601) is blown , check to see that all components in the power supply
circuit are not defective before you connect the AC plug to the AC power supply.
Otherwise it may cause some components in the power supply circuit to fail.
For continued protection against risk of fire,
replace only with same type 2.5A, 250V fuse.